Instruction book
84 6996 0227 40
Atlas Copco vacuum Foodgrade Fluid
Ambient temperature
Element outlet
temperature
Exchange interval *
Maximum time interval *
up to 25 °C
up to 90 °C
4000 hours
1 year
from 25 °C up to 35 °C
from 90 °C up to 100 °C
3000 hours
1 year
more than 35 °C
more than 100 °C
2000 hours
1 year
* Whichever comes first
Important
Always consult Atlas Copco if a timer setting has to be changed.
For the change interval of oil and oil filter in extreme conditions of temperature, humidity
or cooling air, consult your Atlas Copco Customer Center.
Any leakage should be attended to immediately. Damaged hoses or flexible joints must
be replaced.