- 73 -
Design Data Alternator 4) Standard IEC34-1
ISO 8528-3
Make MECCALTE
Model LT3N-160/4
Rated output, class H temperature rise 8 kVA
Rating type acc. ISO 8528-3 "BR" 125/40°C
Degree of protection (IP index acc. NF EN 60-529) IP 21
Insulation stator class H
Insulation rotor class H
Number of wires 4
Electrical power circuit Circuit-breaker 1ph:
Number of poles 2
Thermal release (lt) 40 A
Fault current protection, residual current release, Idn 0.03 A
Circuit-breaker 1ph:
Number of poles 1
Thermal release (lt) 16 A
Magnetic release (lm) 5 x In
Circuit-breaker 1ph:
Number of poles 1
Thermal release (lt) 10 A
Magnetic release (lm) 5 x In
Lights Number of lights 4
Type of lights Metal Halide
Light output 1000 W
Lamps type 9.5 A
Tower height 8.6 m
00_00_HiLight H4_EN.book Page 73 Monday, April 18, 2016 2:10 PM