15
PAGE
Repair Instructions No.181.03/98
PHE 6 H / PHE 6 S
PHE 6 H:
Mounting the
bearing housing
1 Press the rotary shaft seal (6) into the
bearing housing (8).
2 Fit the bearing housing (8) with the
O-ring (7) to the gear housing and
fasten it with secured screws (9).
3 Fit the nosepiece (2) to the bearing
housing (8) and fasten it with secured
screws (3).
4 Push the plastic housing (1) over the gear
housing from the front and secure it with
the connecting ring.
5 Push the back part of the housing (5) over
the gear housing from behind and fasten it
with the screws (4).
Mounting the
armature
1 Push the insulating disk (5) and the
ring (7) over the armature shaft and press
on the armature bearings (4) and (8).
2 Push the bearing sleeve (3) over the ar-
mature bearing (4).
3 Lightly grease the armature bearing (8)
and insert the complete armature into the
machine by turning it.
4 Insert the brush holders (C) into the motor
housing (9). Align them with the adjust-
ment tool (service tool) and fix them with
the screws (B).
5 Push the field (1) into the motor hous-
ing (9) and insert the air deflector ring (2).
Mind the right position!
6 Push the motor housing (9) with the
field (1) and the air deflector ring (2) over
the armature.
7 Fasten the motor housing with two short
screws (A) and two long screws (D).
4
9
2
3
1
5
8
7 6
i
k
j
h
CD
C
1
6
5
4
3
2
8
7
A
B
9