16
PAGE
Repair Instructions No.181.03/98
PHE 6 H / PHE 6 S
Assembling the
handgrip
1 Insert the switch (9) with the capacitor into
the handle shell (7).
2 Insert the connecting cable (H) with the
cable entry sleeve as well as the cable
clamps (D) into the handle shell (7).
3 Fit the handle shell (C) with the holding-
down device to the other handle shell and
fasten them with the four screws (6).
Take care that no cables are jammed
or squeezed.
4 Insert the handgrip holder (4) and the rub-
ber collar (3) into the handle shell (7).
5 Connect according to wiring diagram.
6 Insert the damping element (2) into the
housing.
7 Push the completed pair of handle shells
over the housing (F) and fasten it with the
screws (G).
8 Fasten both Torx screws (8) TX 30 of the
handgrip holder (4) together with the
disks.
9 Insert the handle cover (A) from above
and fasten it with the screw (B).
10Screw down the handle screw (E),steady-
ing the knurled nut (5) at the same time.
Mounting the
carbon brushes
1 Mount the carbon brushes (3) and mount
the cable lugs (h) and (i) on the field.
2 Insert the carbon brushes (3) into the
brush holders (4).
3 Pull up the brush springs (5) of the brush
holders (4) and push them over the carbon
brushes (3).
4 Fasten the carbon brush covers (2) with
the screws (1).
e
a
b
j
k
a
e
b
H
A B
5
E
F
6
7
8
D
C
3
2
9
4
1
G
13
i
h
1
4
2
3
5
14