Preventing ESD problems
The components inside the tool and controller are sensitive to electrostatic discharge. To avoid future mal-
function, make sure that service and maintenance is carried out in an ESD approved work environment.
The figure below shows an example of an appropriate service work station.
Maintenance Instructions
Service recommendations
Preventive maintenance is recommended at regular intervals. See the detailed information on preventive
maintenance. If the product is not working properly, take it out of service and inspect it.
If no detailed information about preventive maintenance is included, follow these general guidelines:
■ Replace any defective or worn parts
Replacing the clock and calendar battery
The controller clock and calendar has a battery backup solution. The disposable battery is of type 3V
Lithium CR2032.
To replace the battery, do the following:
1. Open the front access door of the controller.
2. On the front access door, unscrew the screws on the clock/calendar cover and remove the cover.
3. Remove the old battery and replace it with a new battery of the same type.
4. Re-attach the cover and screws to the front access door.
5. Close the front access door.
Base board fuse
Base board fuse F101 characteristics:
250V AC/10 AT (mfr: Littelfuse type: 0215010.xxP)
Wiring
If it is necessary to change the plug on the mains cable, use the following wiring guide:
Color Input
Brown or black Live
Blue Neutral