Power Focus 6000 LV EN Installation
© Atlas Copco Industrial Technique AB - 9839 1081 01
9
1. Remote start
2. Emergency stop
3. COM ports
4. Battery
5. Cable
6. USB port
7. IAM
8. Digital input
9. Digital output
10. I/O bus
11. Factory Ethernet port
12. Anybus CC
13. Power connector
Installation Instructions
Installing the controller
The controller must be positioned so that the power switch is easily accessible.
For maximum tool performance ensure that the controller is mounted so that free airflow is provided.
This will improve the cooling of the controller.
1. Mount the mounting plate on the wall or steel plate with three M6 screws. If mounting on a wall, make
sure to use the correct wall bracket (plug and screw). If mounting on a steel plate, make sure that the
plate is at least 2 mm thick.
2. Attach the controller to the mounting plate by tilting the controller and then insert the top flange of the
mounting plate into the slot on the rear of the controller. Drop the controller down to engage the lock-
ing mechanism.
3. Open the front access door of the controller.
4. Connect the power cable to the socket.
5. Connect the IAM to the socket on the back of the front access door.
6. Close the front access door.
7. Connect the tool cable to the socket on the underside of the controller.
8. Connect the power cable to a power supply (115/230 V)
9. Turn the power switch on
Emergency stop button
The supply disconnecting device may serve as an emergency stop when it is readily accessible to the op-
erator and it is of the type described in EN 60204-1:2006, 5.3.2 a), b), c) or d). When intended for such
use, the supply disconnecting device shall be colored red and have a yellow background. (Ref. EN
60204-1:2006, 10.7.5).
Configuring remote start for single or multiple controllers
The switch for remote start is found on the connector board located behind the front access door.
Whenever enabling remote start you must for safety reasons implement an emergency stop solution. For
more information about emergency stop, see Emergency stop in Power Focus 6000 LV.