5.4.2 Replacing the oil filter element
Change the oil filters during each oil change.
Place an appropriate drain pan under the oil drain
flexible.
Remove the drain plug from the oil drain flexible
to drain the oil.
Replace the seal of the drain plug.
Install and thighten the drain plug on the oil drain
flexible.
Unscrew the oil filter element (1) from the adapter
head.
Clean the adapter head sealing surface. Lightly oil
the gasket of the new element and screw the latter
onto the adapter head until the gasket is properly
seated, then tighten with both hands.
Top up the engine oil level.
Run the engine for 1 minute and check the oil
level using the oil level dipstick.
Never mix oils of different brands or
types. Use only non-toxic oils where
there is a risk of inhaling delivered
air.
Hot oil and hot surfaces can cause
burns.
Observe all relevant environmental
and safety precautions.
!
!
1
!
Never leave spilled liquids such as
fuel, oil, water and cleansing agents
in or around the generator.
!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco QAX 30 Dd S3A APP and is the answer not in the manual?

Atlas Copco QAX 30 Dd S3A APP Specifications

General IconGeneral
BrandAtlas Copco
ModelQAX 30 Dd S3A APP
CategoryInverter
LanguageEnglish

Related product manuals