- 67 -
Starting the generator and switching the lights
on and off
1. To switch the lamps (HP) on, plug the connector
of the power supply cable towards the lamps
(PSC) in outlet socket X2 of the generator.
2. Check that the main circuit breaker Q1 is switched
off.
3. Start up the generator (see “Operating and setting
Qc1002™”).
4. To switch on the lights, switch on the main circuit
breaker Q1. To switch off the lights, switch off the
main ciruit breaker Q1.
Taking down the lighting tower
1. Check that the mast (M) is turned to the original
position (with the lights directed to the back of the
lighting tower) and locked.
2. To take down the lighting tower follow the
procedure of the erection of the lighting tower in
reversed order.
Additional checks:
– After locking the mast in its horizontal position,
tighten the elevation cable (EC) by turning on the
lever of the winding mechanisme (WM).
– Make sure ALWAYS to retract the stabilizers
(ST).
– After retracting, check that the stabilizers (ST) are
locked
with the appropriate handles (HLS).
Check that the foots of the stabilizers (FS) are
tightened firmly (using the handles HHF and
HLF).
9.5.4.3 Lighting tower maintenance
– Refer to the maintenance instructions mentioned
in the chapter dealing with the “Undercarriage”
option.
– Check the condition of the tower, the tightness of
its bolts and the fixation of the elevation cable
(EC) at least twice a year.
Only start the generator and switch
on the lights when the lighting tower
is erected to the desired position.
When pushing on the emergency
stop the main circuit breaker Q1 is
automatically switched off.