- 49 -
AIR RECEIVER
The air receiver is tested according to official
standards. Carry out regular inspections in conformity
with local regulations.
SAFETY VALVE
Following checks must be carried out:
a check of the opening of the lifting gear, twice a
year. This can be done by screwing the cap of the
valve anti-clockwise.
an annual check of the set pressure according to
local regulations. This check cannot be done on
the machine and must be carried out on a proper
test bench.
COMPRESSOR ELEMENT OVERHAUL
When a compressor element is due for overhaul, it
needs to be done by Atlas Copco. This guarantees the
use of genuine parts and correct tools with care and
precision.
FUEL SYSTEM
Replacing the filter element
1. Unscrew the filter element (2) from the adapter
head.
2. Clean the adapter head sealing surface. Lightly oil
the gasket of the new element and screw the latter
onto the header until the gasket is properly seated,
then tighten with both hands.
3. Check for fuel leaks once the engine has been
restarted.
4. Replace the pre-filter (1).
CLEANING FUEL TANK
The fuel tank can be easily cleaned by taking it out of
the frame.
There is no need to loosen the side panel
.
Refill the fuel tank with clean fuel.
All adjustments or repairs are to be done
by an authorized representative of the
valve supplier.
Observe all relevant environmental and
safety precautions.
Never leave spilled liquids such as fuel,
oil, water and cleansing agents in or
round the compressor.