- 94 -
COMPRESSOR / ENGINE SPECIFICATIONS
REFERENCE CONDITIONS
The inlet conditions are specified at the air inlet grating outside the canopy.
LIMITATIONS
Designation
XRHS 527 Cd - XRHS 1150 CD6 XRVS 487 Cd - XRVS 1050 CD6
Absolute inlet pressure bar(e) 1 1
psi 14.5 14.5
Relative air humidity % 0 0
Air inlet temperature °C 20 20
°F 68 68
Nominal effective working pressure bar(e) 20 25
psi 290 363
Designation
XRHS 527 Cd - XRHS 1150 CD6 XRVS 487 Cd - XRVS 1050 CD6
Minimum effective receiver pressure bar(e) 12.5 15.5
psi 181 225
Maximum effective receiver pressure, compressor
unloaded
bar(e) 22 27
psi 319 392
Maximum ambient temperature
at sea level
°C 45 45
°F 113 113
Minimum starting temperature °C -10 -10
°F 14 14
Minimum starting temperature, with coldstart
equipment
°C -25 -25
°F -13 -13
Altitude capability see separate curve on page 97