- 61 -
Maintenance schedule (hrs)
(continuation of page 60)
Daily 50 hrs
after initial
start-up
Every
250 hrs
Every
500 hrs
Every
750 hrs
Every
1000 hrs
Every
2000 hrs
Yea rly
Empty air filter vacuator valves x
Check engine oil level (if necessary top up) x
Check compressor oil level (if necessary top up) x
Check coolant level x
Check/Fill fuel level (3) x x x
Check functioning of regulating valve
Check function of coolant heater (option) x
Check control panel x
Check on abnormal noise x
Check electrical system cables for wear x
Check for leaks in engine-, compressor-, air-, oil-, or fuel system x x x x x
Check torque on critical bolt connections x x x x
Check electrolyte level and terminals of battery x x x x x
Check engine (minimum and maximum) speed x x x x x
Replace compressor oil filter(s) (5) x x x x
Inspect/Adjust fan belt x x x x x x
Adjust engine inlet and outlet valves (2) x x x x
Hoses and clamps - Inspect/Replace x x x x x
Change engine oil (2) (12) x x x x x x
(to be continued on page 62)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco XRVS 1050 CD4 C3 WUX and is the answer not in the manual?

Atlas Copco XRVS 1050 CD4 C3 WUX Specifications

General IconGeneral
BrandAtlas Copco
ModelXRVS 1050 CD4 C3 WUX
CategoryAir Compressor
LanguageEnglish

Related product manuals