- 54 -
FAULT CODES
There are several parameters that are continuously
watched.
When one of these parameters exceeds its specified
limit the compressor will react depending the present
status of the control box.
Alarmcode Alarmtext Failclass Trigger
1231 FUEL FILL CHECK Warning Xc
1503 INITIAL OVERHAUL REQUIRED Warning Xc
1522 MINOR OVERHAUL WITHIN ** H Warning Xc
1523 MINOR OVERHAUL WITHIN ** D Warning Xc
1524 MINOR OVERHAUL REQUIRED Warning Xc
1552 MAJOR OVERHAUL WITHIN ** H Warning Xc
1553 MAJOR OVERHAUL WITHIN ** D Warning Xc
1554 LOAD PREVENTION - FIRE RISK Inhibit Load Xc
1558 COMP. OIL CHANGE WITHIN ** H Warning Xc
1559 COMP. OIL CHANGE WITHIN ** D Warning Xc
2000 EMERGENCY STOP INPUT Shutdown Xc
2040 REMOTE EMERGENCY STOP Shutdown Xc
2070 COOLANT LEVEL LOW WARNING Warning Xc
2080 COOLANT LEVEL LOW SHUTDOWN Shutdown Xc
2090 P AIRFILTERS HIGH Warning Xc
2100 NO PROJECTFILE DOWNLOADED Warning Xc
2752 NAM OILTRONIX BYPASS CIRCUIT Shutdown After Stop Xc
2762 NAM OILTRONIX CLOSED CIRCUIT Shutdown After Stop Xc
2772 NAM AIRXPERT OPENED CIRCUIT Shutdown Xc
2782 NAM AIRXPERT CLOSED CIRCUIT Shutdown Xc
3000 FUEL LEVEL LOW WARNING Warning Xc
3010 FUEL LEVEL LOW SHUTDOWN Controlled Stop Xc
3020 FUEL LEVEL SENSOR CIRCUIT Warning Xc
3050 VESSEL PRESSURE HIGH WARNING Controlled Stop Xc
3060 VESSEL PRESSURE HIGH SHUTDOWN Shutdown Xc
3070 VESSEL PRESSURE SENSOR CIRCUIT Shutdown Xc
3120 REGULATING PRESSURE SENSOR CIRCUIT Shutdown Xc
3170 AIR DISCHARGE PRESSURE SENSOR CIRCUIT Warning Xc