- 96 -
1)
Free air delivery is measured according to ISO 1217 ed.3 1996 annex D
Typical oil content of compressed air mg/m
3
< 3 < 3
oz/1000 cu.ft 0.003 0.003
Engine oil consumption (maximum) g/h 155.25 155.25
oz/h 5.48 5.48
Compressed air temperature at
outlet valve
°C 110 110
°F 230 230
Noise level
- Sound pressure level (LP), complies with ISO 2151/
EPA under free field conditions at 7 m distance
dB(A) 83.4 83.39
- Sound power level (LW) complies with 2000/14/EC dB(A) 108.62 108.27
- Sound power level (LW) complies with 84/533/EEC
and 85/406/EEC limits
dB(A) - -
Tolerance: +/- 5% 25 l/s (53 cfm) < FAD < 250 l/s (530 cfm)
+/- 4% 250 l/s (530 cfm) < FAD
The international standard ISO 1217 corresponds to
following national standards:
British BSI 1571 part 1
German DIN 1945 Part 1
Swedish SS-ISO 1217
American ANSI PTC9
Designation
XRHS 527 Cd - XRHS 1150 CD6 XRVS 487 Cd - XRVS 1050 CD6