SAFETY DATA SHEET
SDS No. M0042 Effective Date: 02/12/2015
1. IDENTIFICATION
(a) Product identifier used
on the label
FIBERFRAX® DURABOARD® LD
(b) Other means of
identification
Duraboard® LD, Duraboard® LD-RG, Duraboard® LD-HT
(c) Recommended use of
the chemical and
restrictions on use
Primary Use: Refractory Ceramic Fiber (RCF) materials are used primarily in
industrial high temperature insulating applications. Examples include heat shields,
heat containment, gaskets, expansion joints, industrial furnaces, ovens, kilns, boilers
and other process equipment at applications up to 1400°C. RCF based products are
not intended for direct sale to the general public. While RCFs are used in the
manufacture of some consumer products, such as catalytic converter mats and wood
burning stoves, the materials are contained, encapsulated, or bonded within the
units.
Secondary Use: Conversion into wet and dry mixtures and articles (refer to section
8).
Tertiary Use: Installation, removal (industrial and professional) / Maintenance and
service life (industrial and professional) (refer to section 8).
Uses Advised Against
Spraying of dry product.
d) Name, address, and
telephone number
Unifrax I LLC
600 Riverwalk Parkway, Suite 120
Tonawanda, NY 14150
Product Stewardship Information Hotline
1-800-322-2293 (Monday - Friday 8:00 a.m. - 4:30 p.m. EST)
For additional SDSs, visit our web page, http: //www.unifrax.com or call Unifrax
Customer Service at (716) 768-6500
(e) Emergency Phone
Number:
CHEMTREC will provide assistance for chemical emergencies. Call 1-800-424-9300
2. HAZARDS IDENTIFICATION
(a) Classification of the chemical in accordance with paragraph (d) of §1910.1200
The U.S. Occupational Safety and Health Administration (OSHA) Hazard Communication Standard (HCS) 2012
indicates that IARC Group 2B corresponds to OSHA HCS 2012 Category 2 carcinogen classification (see, e.g.,
§1910.1200,
ppendix F, Part D).
(b) Signal word, hazard statement(s), symbol(s) and precautionary statement(s) in accordance with
paragraph (f) of §1910.1200
Under OSHA HCS 2012, RCF is classified as a category 2 carcinogen.
APPENDIX A: Safety Data Sheet Information