Zone (KP) Video Out
1. Using RG6 quad shield coaxial cable terminated with male F connectors, connect the
appropriate KP Video Output 1-6 Terminal [pentagon 2] on the AVH21, as shown in
Figure 94, to the appropriate zone 1-6 video display composite video input. NOTE: The
AVH21 only has video outputs for zones 1-6. Confirm proper connection by zone (Keypad
number). Improper connection will cause operational errors such as misrouted video signals.
2. In larger systems using multiple Hubs, repeat step 1 for all KP Video Output [pentagon 2]
connections to AVH21 #s 1, 2 and 3 for all zones configured for video. Confirm all
connections by zone (keypad number) as shown in Figure 94.
a) AVH21 #1 connects to video displays in zones 1-6
b) AVH21 #2 connects to video displays in zones 8-13
c) AVH21 #3 connects to video displays in zones 15-20.
NOTE: Each AVH21 only has 6 Zone Video Outputs. It is recommended that audio only
zones such as common areas like hallways and patios be connected to zones 7 and 14.
Figure 94 AVH21 Zone Video Output Connections
Door 1
The Door 1 cluster features two latching relays. The Dry Contact Terminal [pentagon 11] would
typically be used with a door lock mechanism that provides voltage for activation by a remote
switch. The +/- Terminal [pentagon 10] would typically be used with a door lock mechanism that
requires external voltage to activate. The +/- Terminal [pentagon 10] has a selectable output
voltage of 12 or 24 VDC.
1. Using 24AWG two-conductor stranded wire, strip approximately ¼” and twist the ends until
there are no loose strands that can cause shorts.
2. Insert the twisted ends into the appropriate slots on the included plug-in connectors and
tighten with a small blade screwdriver. Pull the wire slightly to confirm connection. Check
polarity on both ends. NOTE: Polarity on the AVH21 Dry Contact [pentagon 11] end is not
critical. The Polarity of the Door 1 +/- Terminal [pentagon 10] must be correct or the door
lock device will not function properly and may be damaged.