Version 6.6 21 April 2012
Hardware Installation Manual 5. Cabling the Device
5 Cabling the Device
This section describes how to cable the device:
Connecting to earth or ground – see Section 5.1 on page 21
Connecting to the LAN – see Section 5.2 on page 22
Connecting to FXS interfaces – see Section 5.3 on page 22
Connecting to FXO interfaces – see Section 5.4 on page 23
Connecting to the analog FXS Lifeline telephone – see Section 5.5 on page 24
Connecting to ISDN BRI lines – see Section 5.6 on page 25
Connect BRI interfaces for PSTN Fallback – see Section 5.7 on page 26
Connecting to E1/T1 trunks – see Section 5.8 on page 27
Connecting E1/T1 trunks for PSTN Fallback – see Section 5.9 on page 28
Connect the Dry Contact Relay Alarm System – see Section 5.10 on page 29
Connecting to a computer for serial communication – see Section 5.11 on page 30
Connecting to power – see Section 5.12 on page 31
5.1 Grounding the Device
The device must be permanently connected to earth (ground), using an equipment-earthing
conductor.
Protective Earthing
The equipment is classified as Class I EN60950 and UL60950 and must be
earthed at all times. The device must be permanently connected to the earth
using the screw provided on the rear panel. Use 14-16 AWG wire and a proper
ring terminal for the earthing.
For Finland: "Laite on liltettava suojamaadoituskoskettimilla varustettuun
pistorasiaan."
For Norway: "Apparatet rna tilkoples jordet stikkontakt."
For Sweden: "Apparaten skall anslutas till jordat uttag."
The procedure below describes how to ground the device.
To ground the device:
1. Connect an electrically earthed strap of 16 AWG wire (minimum) to the chassis
earthing screw (located on the rear panel), using the supplied washer.
2. Connect the other end of the strap to a protective earthing. This should be in
accordance with the regulations enforced in the country of installation.