Fast Track Guide 3. Configuring the Mediant 1000
Version 4.8 25 February 2006
11. After modifying the parameters:
• To apply the changes to the selected trunk only, click the Apply Trunk Settings button.
• To apply the changes to all the trunks, click the Apply to all Trunks button.
12. The screen is refreshed, parameters become read-only (indicated by being grayed). The
Stop Trunk button appears at the bottom of the screen.
13. Access the ‘TDM Bus Settings’ screen (Advanced Configuration>TDM Bus Settings). In
the ‘PCM Law Select’ field, select ‘A-law’ for E1 trunks and ‘
µ-Law’ for T1 trunks.
14. To save the changes so they are available after a power fail, click the Save Configuration
button on the main menu bar; the ‘Save Configuration to the Flash Memory’ screen is
displayed. Click the
Save Configuration button in the middle of the screen; a confirmation
message appears when the save is complete.
For more detailed information on configuring the Mediant 1000 trunk settings, refer to the digital
Mediant 1000 User’s Manual.