9.4 Additional maintenance operations in environments with corrosive
agents
If the Radio Remote Control is used in environments where corrosive agents are present
(by way of example: sea water, salt fog, salt...), apply grease to the electrical connections
to protect them.
Only use electrically non-conductive, polyalphaole󰄈n and silicate-based
grease for electrical contacts.
Do not use polyether-, polyoilester- and polyphenyl ether-based grease.
Macon Research's Electric Grease CN 4070 can be used.
Check and replace grease as frequently as shown in the following table:
Type of connection Grease check frequency Re-greasing frequency
BNC connector for antenna every 4-6 months If dirt and impurities are found
Receiving Unit's plug every 4-6 months If dirt and impurities are found
Connectors for Transmitting
Unit's and Receiving Unit's
cable control
e
1 month
If dirt and impurities are found,
and once a year anyway
Contacts of Transmitting Unit,
Battery Charger and battery
weekly
If dirt and impurities are found,
and once every three months
anyway
Key ID 0-1 weekly
If dirt and impurities are found,
and once every three months
anyway
e. It is recommended to disconnect the cable control cable and to store it in a protected place when
it is not in use.
When carrying out this kind of maintenance operations, follow these recommendations:
- make sure that the surface of electrical connections is covered with a layer of grease
and add it if necessary,
- contact the support service of the Machine's Manufacturer if evident oxidation is detected.
AUTEC - Air series