TRANSMITTING UNIT DIAGNOSTIC
If the “machine+radio remote control” system does not start, check if the problem is caused
by the radio remote control or the machine. Before carrying out any verifications, check the
functioning of the machine with the cable control panel:
- if it does not switch on, the problem lies with the machine itself
- if it does switch on, the problem lies with the radio remote control. In this case, proceed as
follows:
ENGLISH
Is the led on with
a steady light?
Is the STOP
button or one
of the movement
actuator inserted?
Release it/them
The battery is
discharged:
replace it with one
that is charged.
Does it continue
to blink quickly?
Clean the contacts
in the battery seat.
Does it continue
to blink quickly?
Does the led
blink quickly ?
If the problem
persists
CALL
TECHNICAL
ASSISTANCE
Carry out
diagnostics
checks on the
receiver unit.
NO
YES
NO
NO
NO NO
NO
If you activate
START,
is the led on with
a steady light?
Does the led
blink slowly ?
YES
YES
YES
YES
YES