20
IT EN FR DE ESIT EN FR DE ES
5.1 - MAIN FUNCTIONS
ON – OFF
- A rapid pressure on the button turns “FRESCO 5000 BACK”. on and o.
When the device is on, the display always shows the last set temperature.
MODE
- Every pressure of the key cycles through the modes MIN, AUTO and MAX. The corresponding icon lights up.
MIN
This corresponds the lowest power setting of “FRESCO 5000 BACK” (lowest performance and lowest compressor
speed – the timer is set for a continued function of 6 hours, after which “FRESCO 5000 BACK” goes o
automatically). (The timer can be modied with the P0 parameter - see the “Changing the settings” section).
AUTO
The management is automatic (performance and compressor speed are managed automatically based on the
temperature required by the user and on the current temperature - the timer is set for a continued function of 4 hours,
after which “FRESCO 5000 BACK” goes o automatically). (The timer can be modied with the P1 parameter - see
the “Changing the settings” section).
MAX
This corresponds to the highest power setting of “FRESCO 5000 BACK” (highest performance and highest
compressor and ventilator speed), after 20 minutes “FRESCO 5000 BACK” goes to the “AUTO” mode.
- When the device is o, if you press the MODE button, you will activate the DEFERRED ACTIVATION mode and the relative icon
lights up: “FRESCO 5000 BACK” will turn itself on automatically after a certain number of hours have elapsed, shown on the
display; the number of hours can be set between 1 and 99 by using the TEMPERATURE (+ / -) buttons..
VENTILATION
- Each pressure (+ / -) corresponds to the increase or decrease of the ventilation speed: you can choose between 6 dierent levels
of ventilation. The display will show the selected level.
- When the device is o, if you press the (+ / -) button, you will activate only the ventilation.
TEMPERATURE
- Each pressure of the (+ / -) buttons corresponds to the increase or decrease of one degree of temperature: from a minimum value
of 17 to a maximum of 32. The display will show the selected temperature.
5.2 - CHANGING SETTINGS
WARNING: before changing any setting, carefully read the following notes.
WARNING: changing the standard settings must be carried out only by qualified personnel. Any change performed without the proper skills
may cause damage to “FRESCO 5000 BACK” and/or to the vehicle.
To access the setting menu, simultaneously press the (+ / -) and (+) buttons while the device is o.
MAX
MIN
AUTO