INSTALLATION
INSTALLATION DRAWING
A
v
en
ue Mercator. 5 - B-1300 Wavre
www.automaticsystems-group.com
DESIGNATION :
BESTEMMING :
DESSINE :
GETEKEND :
DATE :
DATUM :
DOSSIER :
DOSSIER :
VERIFIE :
NAGEZIEN :
ECHELLE :
SCHAAL :
PLAN :
PLAN :
Ce
plan est notre propriété et ne peut être cédé à des tiers ni être recopié sans autorisation écrite de Automatic Systems.
Dit plan blijft onze eigendom en mag niet voorgelegd aan derden noch worden gekopieerd zonder schriftelijke toelating van Automatic Systems.
FIRSTLANE - FL960 / FL970
CF
01/03/2016
------
PW 1/20 CH8823-gb
A
Ne pas mesurer sur le plan.
Niet meten op het plan.
Les dimensions sont données
en mm.
De afmetingen zijn gegeven in
mm.
A3
6 0 0 9 0 0
9 5
7 9 0
9 5
1 9 0 1 9 0
3 5 0
1 3 0 0
3 0 0
1 0 0 0
2 7 0
2 0 09
0 02 0 0
6 0
1 9 0
1 9 0
5 0
9 5
6 0
9 5 1 0 9 0
9 5
1 3 0 0
9 1 0
1
3 0 0
9 8 0 1 2 8 0
C
D
E
A
B
F I X I N G
C L A M P
F I X I N G
C L A M P
C A B L E S
A A
FL960
LEFT
FL960
RIGHT
FL970
LEFT
FL970
RIGHT
F
FIXATIONS :
DRILL
Ø15 DEPTH 100mm FOR LIEB IG B15/30
A
B
C
D
E
F
Note:
In any case, 3m tail cable end must be foreseen
Foresee wiring harnesse s between each unit
Ethernet cable: CAT5
Cables provided by Automatic Systems:
24VDC (intra-equipment): LIYCY 2x0.75²
CAN cable (intra-equipment) LIYCY (STP): 2x2x0.25²(MAX.10m)
Cables to be provided by the client:
control panel cable in 8 pairs 0 . type TPVF
Power supply(230VAC) cable: 3G2.5²
Ground wire (i ntra-equipment): 2 .

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Automatic Systems FirstLane 960 and is the answer not in the manual?

Automatic Systems FirstLane 960 Specifications

General IconGeneral
BrandAutomatic Systems
ModelFirstLane 960
CategorySecurity System
LanguageEnglish

Related product manuals