5–5
Parameter Memory Addresses (continued)
Parameter Description Hexadecimal
Modbus
Decimal *
Octal
Volts/Hertz Parameters
P2.00
Volts/Hertz Settings 0200 40513 1000
P2.01
Slip Compensation 0201 40514 1001
P2.02
Auto-torque Boost 0202 40515 1002
P2.03
Torque Compensation Time Constant 0203 40516 1003
P2.04
Mid-point Frequency 0204 40517 1004
P2.05
Mid-point Voltage 0205 40518 1005
P2.06
Min. Output Frequency 0206 40519 1006
P2.07
Min. Output Voltage 0207 40520 1007
P2.08
PWM Carrier Frequency 0208 40521 1010
P2.09**
Slip Compensation Time Constant 0209 40522 1011
P2.10
Control Mode 020A 40523 1012
Digital Parameters
P3.00
Source of Operation Command 0300 40769 1400
P3.01
Multi-function Input Terminals (DI1 - DI2) 0301 40770 1401
P3.02
Multi-function Input Terminal 3 (DI3) 0302 40771 1402
P3.03
Multi-function Input Terminal 4 (DI4) 0303 40772 1403
P3.04
Multi-function Input Terminal 5 (DI5) 0304 40773 1404
P3.05
Multi-function Input Terminal 6 (DI6) 0305 40774 1405
P3.06
Multi-function Input Terminal 7 (DI7) 0306 40775 1406
P3.07
Multi-function Input Terminal 8 (DI8) 0307 40776 1407
P3.08
Multi-function Input Terminal 9 (DI9) 0308 40777 1410
P3.09
Multi-function Input Terminal 10 (DI10) 0309 40778 1411
P3.10
Multi-function Input Terminal 11 (DI11) 030A 40779 1412
P3.11
Multi-Function Output Terminal 1 (Relay Output) 030B 40780 1413
P3.12
Multi-Function Output Terminal 2 (DO1) 030C 40781 1414
P3.13
Multi-Function Output Terminal 3 (DO2) 030D 40782 1415
P3.14
Multi-Function Output Terminal 4 (DO3) 030E 40783 1416
P3.16
Desired Frequency 0310 40785 1420
P3.17
Desired Current 0311 40786 1421
P3.18
PID Deviation Level 0312 40787 1422
P3.19
PID Deviation Time 0313 40788 1423
P3.20
Desired Frequency 2 0314 40789 1424
P3.30
Frequency Output (FO) Scaling Factor 031E 40799 1436
P3.31**
2nd Source of Operation Command 031F 40800 1437
* For Modbus Decimal addresses used with CLICK PLCs,
insert another zero as the next-to-most-significant digit, e.g., 402333 instead of 42333.
** Some parameters are available only in later firmware versions of DURAPULSE drives.
Refer to P9.39 and “DURA
PULSE Parameter Summary” in Chapter 4 for more information.
Parameter can be set during RUN Mode.
Chapter 5: DURAPULSE MODBUS Communications
DURAPULSE AC Drive User Manual
1st Ed. Rev. D 05/2013