Chapter 4: AC Drive Parameters
4–2
DURAPULSE Parameter Summary
Parameters available only in later firmware versions of DURAPULSE AC drives
Parameters and settings available only with firmware v1.02 and higher:
• P6.30 • P9.39
Parameters and settings available only with firmware v1.04 and higher:
Parameters and settings available only with firmware v1.05 and higher:
• P2.09 • P2.10 settings 04, 05 • P4.13 default = 06 • P6.37
• P3.02~P3.10 settings 19, 20
• P3.11~P3.14 setting 16
• P3.31
• P4.13
• P4.14
• P4.15
• P4.16
• P4.17
• P4.18
• P7.27 settings 02, 03
• P7.28
Parameter Summary
Parameter
*
Description Range*
Default
Setting
User
Setting
Motor Parameters
P0.00
Motor Nameplate Voltage
230V class: 200/208/220/230/240
460V class: 380/400/415/440/460/480
240
480
P0.01
Motor Nameplate Amps Drive Rated Amps x 0.4 to 1.0
Drive
Rated
Amps
x 1.0
P0.02
Motor Base Frequency 50/60/400 60
P0.03
Motor Base RPM 375 to 24,000 rpm 1750
P0.04
Motor Maximum RPM
(Max operation Freq.,
AI1 and AI2 100% value)
P0.03 to 24,000 rpm P0.03
P0.05
Motor Auto Tune
00 Disable
01 Enable P0.06 only
02 Enable P0.06 and P0.07
00
P0.06
Motor Line to Line Resistance
R1
00 to 65535 m액 00
P0.07
Motor No-Load Current Drive Rated Amps x 0.0 to 0.9 (Amps)
Drive
Rated
Amps
x 0.4
* Some parameters and settings are available only in later firmware versions of DURAPULSE drives. Refer to
the beginning of this “DURA
PULSE Parameter Summary” section for more information.
Some parameters and settings are available only in later firmware versions of
DURA
PULSE AC drives. Check parameter P9.39 to determine the firmware version
of your DURA
PULSE drive.
DURAPULSE AC Drive User Manual
1st Ed. Rev. D 05/2013