5–65
DL RX/WX Communication Program (continued)
(Continued next page)
38
Drive #2 Speed Control
bit 60/30Hz
X23
K300
LD
BIN
Drive #2
Speed Ref New
V3020
OUT
39
K600
LD
BIN
Drive #2
Speed Ref New
V3020
OUT
Drive #2 Speed Control
bit 60/30Hz
X23
40
K1
LD
Drive #2
Run CMD New
V3021
OUT
Drive #2 Run/Stop
X25
41
K0
LD
Drive #2
Run CMD New
V3021
OUT
Drive #2 Run/Stop
X25
Rungs 38 & 39 select either 30Hz or 60Hz based on X23.
Rungs 40 & 41 select Run or Stop based on X25.