Chapter 1: Getting Started
1–10
General Specifications (cont.)
Protective Functions
Electronic Thermal, Overload Relay, Auto Restart after Fault,
Momentary Power Loss, Reverse Operation Inhibit, Auto Voltage
Regulation, Over-Voltage Stall Prevention, Auto Adjustable
Accel/Decel, Over-Torque Detection Mode, Over-Torque Detection
Level, Over-Torque Detection Time, Over-Current Stall Prevention
during Acceleration, Over-Current Stall Prevention during Operation
Operator
Interface
Operator Devices 9-key, 2 line x 16 character LCD display, 5 status LEDs
Programming Parameter values for setup and review, fault codes
Status Display
Output Frequency, Motor Speed, Scaled Frequency, Output Current,
Motor Load, Output Voltage, DC Bus Voltage, PID Setpoint, PID
Feedback, Frequency Setpoint
Key Functions
RUN, STOP/RESET, FWD/REV, PROGRAM, DISPLAY, <UP>,
<DOWN>, ENTER
Environment
Enclosure Rating Protected Chassis, IP20
Ambient Temperature -10°C to 40°C (14°F to 104°F)
Ambient Humidity 20 to 90% RH (non-condensing)
Vibration 9.8 m/s
2
(1G) less than 10 Hz, 5.9 m/s
2
(0.6G) 10 to 60 Hz
Installation Location
Altitude 1000m or lower above sea level, keep from corrosive gas,
liquid and dust
Options
Noise filter, input AC reactor, output AC reactor, cable for remote
operator, programming software, Dynamic braking resistor, input fuses
DURAPULSE AC Drive User Manual