B–3
AutomationDirect PLC Modules for Use with DURAPULSE AC Drives (continued)
DL05 PLCs *
D0-05AR
DL05 CPU, 8 AC in / 6 Relay out, 110/220VAC Power Supply. Inputs: 8 AC inputs,
90-120VAC, 2 isolated commons. Outputs: 6 Relay outputs, 6-27 VDC, 6-240 VAC, 2A/pt.
max., 2 isolated commons
D0-05DR
DL05 CPU, 8 DC in / 6 Relay out, 110/220VAC Power Supply. Inputs: 8 DC inputs,
12-24VDC current sinking/sourcing, 2 isolated commons. Outputs: 6 Relay outputs,
6-27VDC, 6-240 VAC, 2A/pt. max., 2 isolated commons
D0-05DD
DL05 CPU, 8 DC in / 6 DC out, 110/220VAC Power Supply. Inputs: 8 DC inputs, 12-24
VDC current sinking/sourcing, 2 isolated commons. Outputs: 6 DC outputs, 6-27 VDC
current sinking, 1.0A/pt. max.
D0-05DD-D
DL05 CPU, 8 DC in / 6 DC out, 12/24VDC Power Supply. Inputs: 8 DC inputs, 12-24 VDC
current sinking/sourcing, 2 isolated commons. Outputs: 6 DC outputs, 6-27 VDC current
sinking, 1.0A/pt. max.
D0-05DR-D
DL05 CPU, 8 DC in / 6 Relay out, 12/24VDC Power Supply. Inputs: 8 DC inputs, 12-24
VDC current sinking/sourcing, 2 isolated commons. Outputs: 6 Relay outputs, 6-27 VDC,
6-240VAC, 2A/pt. max., 2 isolated commons
DL06 PLCs *
D0-06DD1
DL06 CPU, 20 DC in / 16 DC out, 110/220VAC Power Supply, with 0.3A 24VDC Auxiliary
Device Power Supply. Inputs: 20 DC inputs, 12-24 VDC current sinking/sourcing, 5 isolated
commons (4 inputs per common). Outputs: 16 DC outputs, 12-24 VDC current sinking,
1.0A/pt. max., 4 commons non-isolated (4 points per common)
D0-06DD2
DL06 CPU, 20 DC in / 16 DC out, 110/220VAC power supply, with 0.3A 24VDC auxiliary
device power supply. Inputs: 20 DC inputs, 12-24 VDC current sinking/sourcing, 5 isolated
commons (4 inputs per common). Outputs: 16 DC outputs, 12-24 VDC current sourcing
1.0A/pt. max., 4 commons non-isolated (4 points per common).
D0-06DR
DL06 CPU, 20 DC in / 16 Relay out, 110/220VAC Power Supply, with 0.3A 24VDC
Auxiliary Device Power Supply. Inputs: 20 DC inputs, 12-24 VDC current sinking/sourcing, 5
isolated commons (4 inputs per common). Outputs: 16 Relay outputs, 6-27 VDC,
6-240VAC, 2A/pt. max., 4 isolated commons (4 points per common)
D0-06AR
DL06 CPU, 16 AC in / 20 Relay out, 110/220VAC power supply, with 0.3A 24VDC auxiliary device
power supply. Inputs: 20 AC inputs, 90-120 VAC, 5 isolated commons (4 inputs per common).
Outputs: 16 Relay outputs, 6-27 VDC, 6-240 VAC, 2A/pt. max., 4 isolated commons (4 points per
common)
D0-06DD1-D
DL06 CPU, 20 DC in / 16 DC out, 12/24VDC Power Supply. Inputs: 20 DC inputs, 12-24
VDC current sinking/sourcing, 5 isolated commons (4 inputs per common). Outputs: 16 DC
outputs, 12-24 VDC current sinking, 1.0A/pt. max., 4 commons non-isolated (4 points per
common).
D0-06DD2-D
DL06 CPU, 20 DC in / 16 DC out, 12/24VDC power supply. Inputs: 20 DC inputs, 12-24
VDC current sinking/sourcing, 5 isolated commons (4 inputs per common). Outputs: 16 DC
outputs, 12-24 VDC current sourcing, 1.0A/pt. max., 4 commons non-isolated (4 points per
common).
D0-06DR-D
DL06 CPU, 20 DC in / 16 Relay out, 110/220VAC Power Supply. Inputs: 20 DC inputs,
12-24VDC current sinking/sourcing, 5 isolated commons (4 inputs per common). Outputs: 16
Relay outputs, 6-27 VDC, 6-240 VAC, 2A/pt. max., 4 isolated commons (4 points per common)
* “Brick” PLCs may contain some I/O that are not compatible with GS3/DURAPULSE drives.