7 Counter Mode     
46    © Copyright Reserved Autonics Co., Ltd. 
Parameter  Parameter setting value 
Min. reset time 
[RST] 
, unit: ms 
※Set min. width of external reset signal input. 
Input logic 
[SIG] 
NPN: no-voltage input, PNP: voltage input 
※Check input logic (NPN, PNP). 
Prescale 
decimal point
※2
 
[ScDP] 
●
●  4-digit model 
   
※Decimal point of prescale should not set smaller than decimal point [DP]. 
Prescale value 
[SCL] 
※Setting range of prescale value 
 6-digit model: 0.00001 to 99999.9, 4-digit model: 0.001 to 999.9 
Start point 
value 
[STRT] 
※Setting range is linked with decimal point [DP]. 
 6-digit model: 0.00000 to 999999, 4-digit model: 0.000 to 9999   
※When input mode is DN, DN-1, DN-2, start point value does not appear.   
Memory 
protection 
[DATA] 
 
※CLR: Resets the counting value when power OFF.   
   REC: Maintains the counting value when power OFF. (memory protection) 
Key lock 
[LOCK] 
 
※
  lOFF: Unlock keys, key lock indicator turns OFF 
    LOc1: Locks    key, key lock indicator turns ON 
    LOc2: Locks 
,  , 
  keys, key lock indicator turns ON 
    LOc3: Locks ,
  ,  , 
  keys, key lock indicator turns ON 
   
 
 
※1: For 1-stage setting value change model, OUT1 does not appear. The output time of OUT2 is 
   
  displayed as OUtT. 
※2: Decimal point and prescale decimal point 
  Decimal point: Set the decimal point for display value regardless of prescale value.   
  Prescale decimal point: Set the decimal point for prescale value of counting value   
   
  regardless of decimal point of display value.