J-18
CX Series
Input Operation Mode (Counter)
Input mode Counting chart Operation
UP
[
UP
]
INA
H
L
No counting
No counting
0
1
2
3
4
5
6
7
H
L
INB
Count
※
When INA is counting input, INB is no
counting input.
When INB is counting input, INA is no
counting input.
UP-1
[
UP-1
]
INA
H
L
No counting
0
1
2
3
4
5
H
L
INB
Count
※
When INA input signal is rising ( ),
it counts.
※
INA: Counting input
※
INB: No counting input
UP-2
[
UP-2
]
INA
H
L
No counting
0
1
2
3
4
H
L
INB
Count
※
When INA input signal is falling ( ),
it counts.
※
INA: Counting input
※
INB: No counting input
UP-3
[
UP-3
]
INA
H
L
0
1
2
3
5
6
H
L
INB
Count
※
When INA or INB input signal is rising
( ), it counts.
※
INA: Counting input
※
INB: Counting input
Down
[
DN
]
INA
H
L
No counting
No counting
0
n
n-1
n-2
n-3
n-4
n-5
n-6
n-7
H
L
INB
Count
※
When INA is counting input, INB is no
counting input.
When INB is counting input, INA is no
counting input.
Down-1
[
DN-1
]
INA
H
L
No counting
0
n
n-1
n-2
n-3
n-4
n-5
H
L
INB
Count
※
When INA input signal is rising ( ) ,
it counts.
※
INA: Counting input
※
INB: No counting input
Down-2
[
DN-2
]
INA
H
L
No counting
0
n
n-1
n-2
n-3
n-4
n-5
H
L
INB
Count
※
When INA input signal is falling ( ) ,
it counts.
※
INA: Counting input
※
INB: No counting input