E-11
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
power
supply
(Q)
Stepping
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Pressure Sensor
※
Low value setting range : Min. display pressure
<
, ≤ Max. display pressure
-
(3×Min. display range)
※
High value setting range :
, +
(3×Min. display range) ≤ , ≤ Max. display pressure
※
The minimum display unit for hysteresis is fixed to 1.
※
ST1
setting range : Min. display pressure
<
ST1
≤ Max. display pressure
※
HYS1
setting range : Min. display pressure
<
HYS1
≤
ST1
※
Low value setting range : Min. display pressure
<
≤ Max. display pressure
-
(3×Min. display range)
※
High value setting range : Low value + (3×Min. display range) ≤
≤ Max. display pressure
※
In case
HYS1
and
ST1
have the same setting values, it will have the minimum display unit as a hysteresis.
※
ST1
setting range : Min. display pressure
<
ST1
≤ Max. display pressure
-
1% of rated pressure
※
ST2
setting range :
ST1
+ 1% of rated pressure
<
ST2
≤ Max. display pressure
※
If certain detection level difference is not ensured, or setting conditions are not met,
ERR3
message will flash three times and returned
to
ST2
setting mode. Check all setting conditions and set proper setting values.
※
Press
key to change set values and last set value will be saved for level 1 and level 2.
Window comparison output mode [
WIN
]
Hysteresis-Window comparison output mode [
HY-W
]
Automatic sensitivity setting mode [
AUTO
]
SET
=
Sensitivity will be automatically
SET
.
Press
or key to fine-adjust the setting
value between
ST1
and
ST2
.
ST1
+
ST2
2
RUN mode
Press
Key
Press
Key
Press
Key
Press
Key
Press
Key
Press
Key
Press
Key
Press
Key for
3 sec in RUN mode.
ST1
and previously
set value will flash
in turn every 0.5 sec.
ST2
and previously
set value will flash
in turn every 0.5 sec.
SET
and previously
set value will flash
in turn every 0.5 sec.
Press
or Key
to select
ST1
setting value.
Press
or Key
to select
SET
setting value.
Press
or Key
to select
ST2
setting value.
RUN mode
Press
Key
Press
Key
Press
Key
Press
Key
Press
Key
Press
Key for
3 sec in RUN mode.
and previously
set value will flash
in turn every 0.5 sec.
and previously
set value will flash
in turn every 0.5 sec.
and previously
set value will flash
in turn every 0.5 sec.
and previously
set value will flash
in turn every 0.5 sec.
Press
or Key
to select
setting value.
Press
or Key
to select
setting value.
Press
or Key
to select
setting value.
Press
or Key
to select
setting value.
RUN mode
Press
Key
Press
Key
Press
Key
Press
Key
Press
Key
Press
Key for
3 sec in RUN mode.
ST1
and previously
set value will flash
in turn every 0.5 sec.
HYS1
and previously
set value will flash
in turn every 0.5 sec.
and previously
set value will flash
in turn every 0.5 sec.
and previously
set value will flash
in turn every 0.5 sec.
Press
or Key
to select
ST1
setting value.
Press
or Key
to select
setting value.
Press
or Key
to select
setting value.
Press
or Key
to select
setting value.