Do you have a question about the Autonics PSAN Series and is the answer not in the manual?
| Series | PSAN |
|---|---|
| Type | Power Supply |
| Input Voltage | 100-240VAC |
| Output Voltage | 24VDC |
| Operating Temperature | -10 to 60°C |
| Safety Standards | CE, UL |
| Protection | Overvoltage protection, Short circuit protection |
Details specifications for gauge pressure types, models, and ranges.
Lists available pressure types and their corresponding model prefixes.
Details specs for analog voltage and current outputs, including resolution and scale.
Describes the display method and resolution options for pressure units.
Lists available pressure units and their display intervals.
Details display accuracy, dielectric strength, vibration, and environmental conditions.
Covers protection rating, materials used, and cable specifications.
Lists product approval (CE) and unit weights for different types.
Provides detailed dimensional drawings for the pneumatic type sensor.
Shows dimensions for the panel mounting bracket accessory.
Provides dimensions for Fixing Bracket A used for mounting the sensor.
Provides detailed dimensional drawings for the fluid type sensor.
Dimensions for panel mounting and fixing brackets.
Specifies the dimensions for panel cut-outs for mounting.
Lists separate accessories like panel brackets and pressure unit labels.
Illustrates circuit diagrams for analog voltage and current outputs.
Shows the circuit for NPN open collector output.
Shows the circuit for PNP open collector output.
Illustrates circuit diagrams for Hold/Auto Shift input functionality.
Identifies and explains the functions of the front panel display and keys.
Outlines the main parameter settings accessible via the M key and other keys.
Details the procedure for executing zero-point adjustment, including conditions and error handling.
Explains how to access and navigate the parameter setting menu.
Describes how to navigate and set parameters within the RUN mode.
Details the procedure for setting the pressure unit.
Explains how to select the output operation mode (e.g., Hysteresis, Window comparison).
Details how to set the output type (e.g., Normally Open, Normally Closed).
Explains how to adjust response time for chattering prevention.
Sets hysteresis detection levels (SE1, SE2) and values (HY51, HY52).
Sets the scale for analog voltage output (1-5VDC) relative to pressure.
Sets the scale for analog current output (4-20mA) relative to pressure.
Selects external input functions for Hold/Auto Shift input.
Selects the control output for Auto Shift function.
Configures key lock levels (LOC1, LOC2, OFF) to restrict operations.
Sets detection levels and hysteresis values.
Sets high/low limits and combines window/hysteresis modes.
Automatically adjusts detection sensitivity based on applied pressure.
Forces output OFF regardless of setting, allowing manual ON/OFF control.
Allows changing pressure units and selecting output modes.
Configures control output types and response time for stability.
Details scaling for analog outputs and the auto shift function.
Describes the Hold function and its impact on pressure value and output.
Explains saving measured pressure as a reference for correct judgment.
Details the levels of key lock (LOC1, LOC2, OFF) and their operational restrictions.
Sets pressure value to zero when port is open to atmospheric pressure.
Memorizes max/min pressure to diagnose system malfunctions.
Lists error codes and their troubleshooting steps.
Sets detection levels and hysteresis values.
Sets high/low limits for pressure detection within a specific range.
Combines hysteresis and window comparison modes.
Automatically adjusts detection sensitivity based on applied pressure.
Forces output OFF, allowing manual ON/OFF control.
Allows selection of various pressure units for the sensor.
Explains the five available control output modes.
Sets output types (Normally Open/Closed) for Out1 and Out2.
Describes the Hold function and its impact on pressure value and output.
Sets response time to improve control output stability.
Details scaling for analog voltage and current outputs.
Corrects set points using measured pressure as reference for changing initial pressure.
Explains saving measured pressure as reference for correct judgment.
Details the levels of key lock (LOC1, LOC2, OFF) and their operational restrictions.
Sets pressure value to zero when port is open to atmospheric pressure.
Memorizes max/min pressure to diagnose system malfunctions.
Lists error codes and their troubleshooting steps.
Details pressure port types and connection using one-touch fittings.
Explains installation of separately sold brackets and protection covers.
Lists important warnings regarding corrosive/flammable gases, wiring, and environmental contact.
Loading...