E-10
PSAN Series
Press Key
Press
Key
Press
Key
Press
Key
Press
Key
Press
Key
Press
Key
Analog voltage output type
(PSAN-
V- )
Analog current output type
(PSAN-
A- )
Hold/Auto shift input type
(PSAN-
H- )
1V scale setting
5V scale setting
※
1
※
1
※
3
※
2
※
2
Key Lock
4mA scale setting
20mA scale setting
Select external input function
Select the control output for
Auto shift function
● Select external input function ● Select the control output for Auto shift function
※
1:
(voltage output)/ (current output)and previously set pressure value will flash in turn every 0.5 sec.
Press
or key to set analog output scale value for 1V and 4mA.
Setting range: Min.rated pressure ≤
, ≤ 90% of rated pressure
(Press
key for 1 sec to save selected pressure value as a scale value for 1V and 4mA and move to
next mode.)
※
2:
(voltage output)/ (current output) and previously set pressure value will flash in turn every 0.5 sec.
Press
, Key to set analog output scale value for 5V and 20mA.
Setting range:
, +10% of rated pressure ≤ , ≤ Max. rated pressure
(Press
key for 1 sec to save selected pressure value as a scale value for 5V and 20mA and move to
next mode.)
※
3:
and previously set control function will flash in turn every 0.5 sec. Press , key to select
external function.(Press
key for 1 sec to save selected function and move to next mode.)
will flash in turn with previous setting parameter. Press , key to select key lock setting.
(Press
key for 1 sec. to save selected lock setting. Then, it will be returned to pressure unit setting mode.)
※
When pressing
key for 3 sec. in the middle of parameter setting, current setting value will be saved in EEPROM and it will be
returned to RUN mode.
※
All settings are saved in EEPROM regardless of power failure. Make sure that EEPROM has a limited write life cycle(100,000 times).
※
setting range : Min. display pressure
<
≤ Max. display pressure
※
setting range : Min. display pressure
<
≤
※
setting range : Min. display pressure
<
≤
Max. display pressure
※
setting range : Min. display pressure
<
≤
Hysteresis mode [
HYsM
]
Preset setting
※
Refer to E-12 page.
RUN mode
Press or Key
to select
setting value.
Press
or key
to select
setting value.
Press
or key
to select
setting value.
Press
or key
to select
setting value.
Press
Key
Press
Key
Press
Key
Press
Key
Press
Key
and previously
set value will flash
in turn every 0.5 sec.
and previously
set value will flash
in turn every 0.5 sec.
and previously
set value will flash
in turn every 0.5 sec.
and previously
set value will flash
in turn every 0.5 sec.
Press Key for
3 sec in RUN mode.