H-80
TZN/TZ Series
A) In case of sensor input : K(CA), J(IC), R(PR), E(CR), T(CC), S(PR), N(NN), W(TT), DPt 100Ω, JPt 100Ω
B) In case of voltage input : 1-5VDC, 0-10VDC
C) In case of current input : DC4-20mA
SW1
SW1
SW1
SW2
SW2
SW2
SW1:1
SW1:2
SW1:2
SW2: V
SW2: V
SW2:
mA
1 1
2 2
2 2
V
V
V
mA
mA
mA
Input type and range
Input type switch
Factory default of input type switch
: Temperature sensor input.
Please select B) or C) according to input specication when it is voltage or current.
Input type Display Input range(
) Input range(
)
Thermocouple
K(CA) H
KCaH
-100 to 1300
-148 to 2372
K(CA) L
KCaL
-100.0 to 999.9
This mode cannot be used as
J(IC) H
JIcH
0 to 800
32 to 1472
J(IC) L
JIcL
0.0 to 800.0
This mode cannot be used as
R(PR)
R PR
0 to 1700
32 to 3092
E(CR) H
ECrH
0 to 800
32 to 1472
E(CR) L
ECrL
0 .0~800.0
This mode cannot be used as
T(CC) H
TCcH
-200 to 400
-328 to 752
T(CC) L
TCcL
-199.9 to 400.0
This mode cannot be used as
S(PR)
S PR
0 to 1700
32 to 3092
N(NN)
NN
0 to 1300
32 to 2372
W(TT)
U TT
0 to 2300
32 to 4172
RTD
JPt100Ω H
JPtH
0 to 500
32 to 932
JPt100Ω L
JPtL
-199.9 to 199.9
-199.9 to 391.8
DPt100Ω H
DPtH
0 to 500
32 to 932
DPt100Ω L
DPtL
-199.9 to 199.9
-199.9 to 391.8
Analog input
0-10VDC
A--1
-1999 to 9999
-1999 to 9999
1-5VDC
A--2
-1999 to 9999
-1999 to 9999
DC4-20mmA
A--3
-1999 to 9999
-1999 to 9999