1/17/03
SOFT TOUCH TROUBLESHOOTING CONT’D
**If the service light comes on, count the number of flashes and see below.
?? 3 RED FLASHES – very low amps with Salt OK
o V1.4 or older - scaled cell or failed cell
o Power Supply may have failed or improperly wired.
?? Check the Power Supply for Output. If you do not get a Volt reading the power
supply is bad
How to test: The Power Supply has built in diagnostic test (See page 13 of your manual for procedures),
or use a 957B tester, put tester in Power Supply mode or a Multimeter and test for Volts.
?? Verify unit and incoming voltage match.
o Cell cord may have failed
?? Check Cell cord for Continuity
How to test: Use a Multi Meter and test for continuity. Center hole is the black wire.
o Cell Failure
?? If you get High Volts and Low Amps your cell is bad.
How to test: The Power Supply has built in diagnostic test (See page 13 of your manual for procedures),
or use a 957B tester, put tester in Cell mode and test for volts and amps.
?? 4 RED FLASHES – Bad Temperature Sensor (salt will not be temperature compensated)
o Replace Tri Sensor