Electrical Work
You will need to have a licensed, certified Electrician available at some point during the installation.
⚠ DANGER All wiring
must
be performed by a licensed, certified Electrician.
The Electrician needs to do these things:
• Connect the selected power source to the bottom of the Power Disconnect
Switch. Required. This is generally done when the Power Unit is being connected.
• Connect the Power Unit to the top of the Power Disconnect Switch. Required. This is
generally done when the Power Unit is being connected.
• Install a
Thermal
Disconnect Switch. Optional. BendPak recommends connecting a
Thermal Disconnect Switch or overload device (not supplied) to make sure the equipment shuts
down in the event of an overload or an overheated motor.
Select a Site
Keep the following in mind when selecting a site for your Autostacker:
• Enough space. Make sure there is adequate space for the Autostacker on all four sides, plus
enough height for the Vehicles you will be lifting. If architectural plans are available, use them to
make sure there is adequate space for your planned layout.
• No overhead obstructions. Make sure the site is free of overhead obstructions such as
heaters, building supports, electrical lines, lights, and so on.
• Concrete specifications. Do not install the lift on cracked or defective Concrete; additionally,a
Anchor Bolts must be at least 6 inches from expansion joints in the concrete or from a wall. Make
sure the concrete is at least 4.25 inches thick, 3,000 psi, and cured for at least 28 days if recently
poured. Make sure the floor is defect-free, dry, and level.
⚠ WARNING Do not install your Autostacker on a surface with 3° or more of slope. A 3° degree
slope or greater could lead to property damage, personal injury, or death.
• Power. You will need a power source available near the Console.
• Operating temperature. Lift is designed to be used between temperatures of 0°F to 104°F
(-20°C to 40°C).
• Indoor installation. Autostacker is designed for
indoor installations
.
• Outdoor installation. Autostacker is not designed for outdoor use. It has an operating ambient
temperature range of 0ºF to 104ºF (-20ºC to 40ºC).
• Second floor installs. Do not install the Autostacker on a second floor or elevated floor without
first consulting the building architect and getting their approval.
• Dress properly. Wear protective gear (like safety goggles, helmet, heavy gloves, suitable
working clothes, safety boots, ear protection, and so on) when installing Autostacker. Do not wear
loose clothing or jewelry; contain long hair; keep hair and clothing away from moving parts.
⚠ WARNING
Always
wear appropriate protective gear when working on the Autostacker.
Important: Your Autostacker Lift is supplied with installation instructions and concrete fasteners
that meet the criteria set by the current American National Standard “Automotive
Lifts – Safety Requirements for Construction, Testing, and Validation” ANSI/ALI
ALCTV. Lift buyers are responsible for any special regional, structural, or seismic
anchoring requirements specified by any other agencies or codes, such as the
Uniform Building Code or International Building Code.