Autostacker™ Parking Lift 44 P/N 5900248Rev. B May 2021
Maintenance
Routine maintenance and adjustments should be carried out on a regular basis. For more complex
maintenance and repairs, contact your independent maintenance contractor.
Routine maintenance and adjustments are the
responsibility of the owner/user
and are
not
covered under warranty.
DANGER: Before performing any maintenance on your Autostacker, make sure it is
completely disconnected from power
. If your organization uses
Lockout/Tagout policies, make sure to implement them after connecting to a power
source.
To maintain your Autostacker:
Daily: Keep the Autostacker clean. Wipe up any spills, clean any dirt.
Daily: Make a visual inspection of all moving parts and check for damage or excessive wear.
Replace any damaged or worn parts before using the Lift.
Daily. Check all Hydraulic connections for any leaks.
Daily: Make sure Safety Locks are in good working condition. Do not use your Autostacker if the
Safety Locks are damaged or excessively worn.
Twice a Week: Sweep the Bases, removing all debris. Pay special attention to the Safety Locks
and the wheel tracks; if these areas are dirty, the Lift may not work normally.
Weekly: After cleaning the wheel tracks, apply a lubricant (WD-40®, for example) to the wheel
tracks to help them roll easily. The wheels are self-lubricating.
Weekly: Check all controls, including emergency stop, to make sure they are functioning
normally.
Weekly: Check all labels on the Autostacker. Replace them if they are illegible or missing.
Every Two Weeks: Lubricate the Grease Fittings on the Lift.
Monthly: Check the Hydraulic Fluid levels. Refill if low.
WARNING When accessing the Power Unit inside the Console for maintenance, do not use the
Back Panel as the point of entrance; the Power Unit is mounted to the Back Panel.
If the Back Panel is removed, the weight of the Power Unit may cause it to fall over
and risk product damage and/or personal injury to anyone nearby.
Every Two Months: Check all Bolts to make sure they are tight. If not, tighten them.
Every Three Months: Damp wash all exposed surfaces to protect against corrosive debris.
Every Six Months. Check the electrical wiring for loose connections; if you find any, secure
them.
WARNING Do not operate your Autostacker if you find issues; instead, take it out of service,
then contact your Autostacker dealer, visit autostacker.com/support, email
support@autostacker.com, or call (888) 977-8225.