ADVANCED
change advanced settings of the heater:
o SHUTDOWN
VOLTAGE
set voltage and time for battery protection.
If the actual voltage of the power supply is lower than the set
voltage for the set duration, heater shuts down and
operation modes cannot be activated.
o THERMOSTAT
change default values for temperature rise and drop for
thermostat mode. MAX from 1°C to 3°C, MIN from 1°C to 7°C;
o INFO
displays information about serial numbers and software
versions:
Heater serial number
Heater software version
Control panel serial number
Control panel software version
Total heater operating hours
4.4. PRE-HEATER (for liquid heaters)
Settings menu “Pre-heater” is disabled when Flow 5 is operating.
For Flow 14D in “Advanced” settings only “Info” and “Shutdown voltage” options
are available.
INFO
displays the same information as for air heaters.
AUXILIARY
set and enable/disable auxiliary mode. When auxiliary mode is
enabled, pre-heater starts when engine starts and maintains set
temperature of the coolant. Temperature range for auxiliary mode
is 75°C to 95°C.
TEMPERATURE
set default temperature for coolant in heating mode. Temperature
range is 20°C to 95°C.
ADVANCED
change advanced settings of the pre-heater:
o THERMOSTAT
enable/disable and configure thermostat mode;
CIRCULATION
when heating in thermostat mode, coolant pump will always
continue to circulate the coolant, even when heater is
switched off.
HYSTERESIS
change default values for temperature rise and drop for
thermostat mode. MAX from 1°C to 3°C, MIN from 1°C to 7°C.
o START PUMP
starts coolant pump for the purpose to bleed the system
after installation. Pump is working while message “Pump
enabled” is displayed. Pressing the back button, switches the
pump off.
o SHUTDOWN
VOLTAGE
set voltage and time for battery protection (same as for air
heaters).