Operation manual
Control panel PU-27
EN
More information https://www.caravansplus.com.au

Other manuals for AUTOTERM PU-27

Question and Answer IconNeed help?

Do you have a question about the AUTOTERM PU-27 and is the answer not in the manual?

AUTOTERM PU-27 Specifications

General IconGeneral
BrandAUTOTERM
ModelPU-27
CategoryControl Panel
LanguageEnglish

Summary

1 Introduction

2 Warranty and Liability

3 Safety Precautions

4 Control Panel Purpose

5 Control Panel External View

6 Starting Control Panel Operation

7 Main Menu Navigation

8 Timers Settings Menu

9 Fast Access Timer Activation

10 Hydronic Pre-Heater Settings

Twait Preheater Setting

Fluid temp for standby mode. Adjustable +20 to +95 °C.

Warming Up Modes

Configures auto/manual heater operation based on engine status.

Twait Warm Up Temperature

Sets additional heater temp. Default +85°C, range +75 to +95°C.

Wait Mode Pump Operation

Defines pump behavior in standby: continuous or synchronized with heater.

Interior Heater Activation

Controls interior heater by fluid temp, with adjustable activation threshold.

Pump with Engine Activation

Enables pump operation with engine start for coolant circulation.

Pump Type Selection

Chooses pump type (Bosch or ADVERS) based on pre-heater configuration.

Alarm Channel Control

Configures pre-heater control via alarm system if a free channel is available.

Reset Settings to Default

Resets all pre-heater settings to their factory default values.

11 Air Heater Settings

Temperature-Based Operation

Sets operation based on heater, panel, or exterior temperature sensors.

Power-Based Operation

Sets operation based on power level, with power value adjustable from 0 to 9.

Standby Temperature Setting

Defines the temperature threshold for switching to standby mode.

Ventilation Mode Control

Configures ventilation mode (ON/OFF) for air pump operation in standby.

12 Control Panel Parameters

Indicator Lighting Settings

Configures indicator light time (10-120s, continuous) and brightness (0-4).

Start Button Behavior

Defines action for short press vs. long press for heater/pump start.

Clock Time Correction

Adjusts clock accuracy for temp variations, range -59 to +59 sec/day.

Key Illumination

Enables or disables the backlighting for control panel keys.

13 Time Settings

14 Language Settings

15 Software Version Display

16 Operating Time Settings

17 Hydronic Pre-Heater Start

18 Air Heater Start

19 Malfunctions and Error Codes

Introduction to PLANAR Heaters

Safety Instructions for Air Heaters

Heater Control Options

PU-5 TM Control Panel

Features unlimited duration startup, capacity/temperature regulation, and LED status.

PU-22 TM Control Panel

Offers unlimited startup, capacity/temp control, ventilation modes, and sensor operation.

GSM Modem Functionality

Enables heater start/shutdown, time setting, and power/ventilation control.

Remote Control Features

Allows starting heater for 2 hours or operation at max power control mode.

Kit Contents

Manufacturer Responsibility

Automatic Control Features

Maintenance Recommendations

Troubleshooting Malfunctions

Technical Specifications (8 DM Models)

Technical Specifications (2 D;4 DM2 Models)