This menu is only intended for timer activation.
Timers cannot be edited in this menu.
Action of timers activation menu keys:
Keys
Action
Navigation between timers.
Timer activation / deactivation.
Exit from this menu to the main screen
10 Hydronic pre-heaters settings menu
BINAR-5S heater settings menu:
Action of Settings menu keys:
Keys
Action
Navigation through the menu items
Exit from menu to the main screen
Change menu item value
Settingsmenu items:
Twait preheater
Fluid temperature at which the pre-heater switches to standby mode
(heater shuts off and pump continues to operate). When the fluid
temperature drops, the pre-heater exits standby mode (the heater starts
again). The default value for the switch to standby mode is +88 °C.
The temperature for the switch to standby mode can be set in the +20
to +95 °С range.