17
17. AV-2004/48 Programming Sheet Version 3.06
Factory Default Program is as shown in table; Blank Square means no default program
TELEPHONES SIGNAL & AUTO ARMING TEST TIME
Tel. 1 is also ‘Follow Me’. Maximum 16 digits + 4 pauses each
Tel. Number. Tel. 2 and 3 are communicator option.
Test signal to central station (014), enter time in 24 hour format.
Codes are defined at Addresses: 052, 073, 237, 255.
To insert * in the phone number; Program system to dial in DTMF, Hold-down keys # and * (as panic), ‘A’ will
be displayed. For Pause during dialing, hold-down key ‘0’.
Zones 5-8 are applicable with AV-2048
ZONE FEATURES
Green Zone (one shot alarm)
NO-EOL Resistor
(not @ 2048)
Enable Zone Tamper
(not @ 2048)
Fast or Very Slow Response **
N.O. (normally open) zone
Values marked with ( ) are the factory default programming
Zone 4 / 8 (2048) as aux. key
Tel. Line Test at Disarmed
Tel. Line fail activates buzzer
Tel. Line fail activates siren
Dialer Report AC Power Fail
Add. 052, CS test day:
1 - Sun 2 – Mon, 3 – Tues, 4 – Wed., 5 – Thu., 6 – Fri., 7 – Sat., 8 - All week's days, 0 – Clear all
TIME-OUTS
Note: Address 059 adjusts the response time of zones selected as ‘Fast Response’. If Slow Response selected, the value in address
059 is in minutes, also set address 075-4.