- 4 -
User Manual
Electrical
Please ensure that the required voltage of the compressor is being supplied at all times. Low or high
voltage can detrimentally affect the refrigeration unit.
All units should be plugged into a grounded and properly-sized electrical outlet with appropriate
overcurrent protection. Please refer to the electrical requirements on the nameplate.
• Please make sure that your unit has its own dedicated outlet.
• Do not use an extension cord.
Temperature Controls
Refrigerant LED - Compressor is on
Fan LED - Fan is on
Defrost LED - Defrost cycle is running
Functions
Adjusting the Temperature
Your new refrigerator or freezer is already factory-set to run at optimum temperatures for food
safety and should require no adjustments.
Refrigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a
maximum temperature of 40 degrees Fahrenheit.
Adjusting the temperature changes the minimum temperature your unit will run at. Your unit will not
run constantly at this setting. To change it, follow t
hese instructions:
Digital Control Units
• Hold “SET” for 1 sec. The display will flash the current minimum temperature.
• Use the arrow buttons to adjust the minimum temperature you want it to run at.
• Press “SET” again to save your settings
Always remember to calculate the differential if you change the minimum temperature setting. The
cabinet temperature will fluctuate up to +7 degrees over your set minimum temperature as the
compressor runs and shuts off. Setting the temperature too high will result in unsafe maxi
mum
temperatures.