The Ethernet Routing Switch 3500 series does not have a power switch. When you connect
the AC power cord to a suitable AC power outlet, the switch powers up immediately.
Connect the AC power cord to the back of the switch, and then connect the cord to a power
outlet.
Figure 1: Connecting the AC power cord to the Ethernet Routing Switch 3500 Series
Connect the AC power cord to the back of the switch, and then connect the cord to a power
outlet.
AC power specifications
The following table describes the AC power specifications for the Ethernet Routing Switch 3500
Series.
Model
Input current Input voltage
(rms)
Power
consumption
Thermal
rating
3510GT Maximum 0.18 A 100–240 VAC
at 50–60 Hz
Maximum 18 W 61Btu/h
maximum
3510GT-PWR+ Maximum 2.1 A 100–240 VAC
at 50–60 Hz
Maximum 210 W 156 Btu/h
maximum
3524GT Maximum 0.28 A 100–240 VAC
at 50–60 Hz
Maximum 28.5 W 95 Btu/h
maximum
3524GT-PWR+ Maximum 5.0 A 100–240 VAC
at 50–60 Hz
Maximum 500 W 357 Btu/h
maximum
AC power specifications