Overview

This document serves as the user's manual for the Avvolta Portable Air-conditioner, models A015A-12C, A015A-14C, and A015A-16C, which utilize R290 refrigerant gas. It provides essential information for proper use, maintenance, and installation of the appliance.

Function Description

The Avvolta Portable Air-conditioner is a versatile household appliance designed to regulate indoor temperature and humidity. It offers multiple functions including refrigeration (cooling), heating, dehumidification, and air supply (fan). Its compact structure, economical performance, and low noise make it suitable for various settings such as bedrooms, offices, and other places.

Important Technical Specifications

  • Models: A015A-12C, A015A-14C, A015A-16C
  • Refrigerant: R290 (flammable refrigerant gas)
  • Power Supply: 220-240V/50Hz
  • Cooling Operating Temperature Range: 17°C - 35°C
  • Heating Operating Temperature Range: 15°C - 25°C
  • Minimum Room Area for Installation/Operation/Storage:
    • 5000Btu/h, 7000Btu/h, 8000Btu/h models: 4 m²
    • 9000Btu/h, 10000Btu/h, 10500Btu/h models: 12 m²
    • 12000Btu/h, 14000Btu/h, 16000Btu/h, 18000Btu/h models: 15 m²
  • Exhaust Hose Length (for effective heating/cooling): Not more than 400mm, kept parallel and not bent.
  • Minimum Clearance from Filter Side to Wall/Obstacles: 500mm
  • Power Outlet Specifications: Not less than 10A, firm and secure.

Usage Features

  • Control Panel & Remote Control: The unit can be operated via a control panel on the device or a remote control. The remote control features temperature selectors (up/down), fan speed selector, mode selector, hourly programming (timer), and an On/Off switch.
  • Modes of Operation:
    • Cooling: Adjust temperature between 17°C and 30°C. Fan speed can be set to LOW, MEDIUM, HIGH, or AUTO. In AUTO mode, the machine adjusts cooling capacity based on room temperature relative to the set temperature.
    • Heating: Adjust temperature between 15°C and 25°C. Fan speed can be selected.
    • Dehumidification: In this mode, wind speed is not adjustable (locked in low wind operation), and the exhaust hose is not required.
    • Fan Speed: Selectable between LOW, MEDIUM, HIGH, or AUTO.
  • Programmable Timer (TIMER-ON/TIMER-OFF): Allows users to set a time (1-24 hours) for the unit to automatically turn on or off.
  • Automatic Evaporation and Drainage: In refrigeration mode, the machine automatically evaporates condensed water and drains it out of the exhaust hose, eliminating the need for manual drainage, provided the drain plug is installed.
  • Drainage (Dehumidification/Heating Mode): For continuous drainage in dehumidification or heating mode, the plug "A" in the drain hole should be removed, and an appropriate drainage pipe installed.
  • Water Full Alarm (E4 Code): When the internal water tank is full, a water indicator illuminates, followed by an "E4" code on the display, and the compressor stops. Draining the water through the drainage pipe will clear the error and resume operation.
  • LED Display: Shows the currently set temperature, timing time, or fault codes.
  • Safety Precautions:
    • Ensure constant ventilation and that inlet/outlet are not blocked.
    • Operate on a horizontal surface to prevent water leakage.
    • Do not operate in explosive or corrosive atmospheres.
    • Wait at least 3 minutes before restarting after shutdown to protect the compressor.
    • Use a separate, dedicated power supply.
    • Avoid direct sunlight and heat sources to improve refrigeration capacity.
    • Close doors and windows during dehumidification.

Maintenance Features

  • Air Filter Cleaning: The strainer (air filter) should be cleaned every two weeks. To clean, remove the strainer overlay, soak it in warm water (about 40°C) with a neutral detergent, rinse off the lotion, and dry it in a cool place before re-installing.
  • Storage (Quarterly Preservation):
    1. Unplug the unit and run it for half a day until the water is blown dry.
    2. Shut down and unplug the power.
    3. Wipe the surface of the machine with a damp cloth and dry it with a dry cloth.
    4. Roll up the power cord.
    5. Cover the machine in a dry place with a plastic bag.
  • Exhaust Hose Removal: The exhaust hose can be removed by rotating it in the arrow direction for both cooling and heating configurations.
  • Self-Diagnosis Function: The unit provides light prompts for self-diagnosis, displaying error codes (E1, E2, E4) to indicate specific issues such as temperature sensor shorts or a full water tank, guiding users or technicians on troubleshooting steps.
  • General Safety Instructions for Maintenance (R290 Refrigerant):
    • Thoroughly read all warnings.
    • Use only manufacturer-recommended tools for defrosting and cleaning.
    • Store in a room without continuously operating ignition sources.
    • Do not pierce or burn the appliance.
    • Be aware that refrigerants may not contain an odor.
    • Ensure the appliance is installed, operated, and stored in a room with a floor area larger than the specified minimum.
    • Do not use means to accelerate defrosting or cleaning other than those recommended.
    • The appliance must be placed in an area without any continuous sources of ignition.
    • Do not puncture or burn.
    • The appliance contains R290 refrigerant gas.
    • R290 is a refrigerant gas that complies with European directives; do not puncture any part of the refrigerant circuit.
    • If the appliance is installed, operated, or stored in an unventilated area, refrigerant leaks could result in fire or explosion due to ignition by electric heaters, stoves, or other sources of ignition.
    • The appliance must be stored in a way that prevents mechanical failure.
    • Individuals working on the refrigerant circuit must have appropriate certification.
    • Repairs must be performed by qualified personnel under supervision of an individual specified in the use of flammable refrigerants.
    • The appliance is for indoor use only.
    • Do not use the unit on a socket under repairs or not installed properly.
    • Avoid placing the unit near sources of fire, areas where oil is likely to splash, direct sunlight, or where water is likely to splash.
    • Do not insert fingers or rods into the air outlet.
    • Keep the unit upright during transport and storage.
    • Before cleaning, always turn off or disconnect power.
    • When moving the air conditioner, always turn off and disconnect power, and move it slowly.
    • To avoid fire, the air-conditioner shall not be covered.
    • All air-conditioner sockets must comply with local electric safety requirements.
    • Children should be supervised and not play with the appliance.
    • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons.
    • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
    • Children should not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
    • The appliance shall be installed in accordance with national wiring regulations.
    • Details of type and rating of fuses: T, 250V AC, 2A or higher.
    • This product should not be disposed of with other household wastes; it should be recycled responsibly.
    • Contact authorized service technician for repair or maintenance.
    • Do not pull, deform, or modify the power supply cord.
    • Compliance with national gas regulations shall be observed.
    • Keep ventilation openings clear of obstruction.
    • Any person involved in working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority.
    • Servicing shall only be performed as recommended by the equipment manufacturer.
    • Do not operate or stop the unit by inserting or pulling out the power plug.
    • Unplug the unit if strange sounds, smell, or smoke comes from it.
    • If any parts damage, contact the dealer or a designated repair shop.
    • In case of any damage, turn off the air switch, disconnect power, and contact the dealer or a designated repair shop.
    • The power cord shall be firmly grounded.
    • To avoid danger, if power cord is damaged, turn off the air switch and disconnect power. It must be replaced by the dealer or a designated repair shop.