- 62 -
O.C.#
1 (1 .. 32)
Says output sp.
YES
Says OC number
YES
Vocal word OC
0 (0 .. 415)
By entering a value different from zero (0) in the programming step “OC vocal word”, it is possible to customise
the vocal communication of the O.C. output state (See telephone table).
Open Collector Number (1..32): Select the O.C. output to be customised and subsequently press (ENT).
Says output speech (communicates the telephone output): By setting “YES” the word OUTPUT is
communicated in vocal
Says O.C. number (communicates number of O.C. output): By setting “YES” the NUMBER OF O.C. is
communicated in vocal
OC vocal word: By setting a numerical value different from “0”, the control panel will communicate the word
associated to the value (see telephone table) enabling to customise the communication.
Press (CLR) to vary
Enter number to be set
Press (ENT) to conrm
Remote handling
ENT 
Tel. num. #
*********************
Tel. num.: this telephone number is dedicated to the re-programming of the control panel.
Account code: client code that will be used for the re-programming and downloading of the events memory.
N.B.: The Account Code must match the Customer Code assigned in the XWIN programme
N.B.: use keys 0 to 9 to enter the Account code
Remote handling
Account code
0 0 0 0 0 0
SIA - IP Receiver
SIA-IP Receiver
ENT 
A
ENT 
B
ENT 
User Password
IP Addr
Socket Port
0
IP Addr
Socket Port
0
GPRS/WEB IP interface
“A” and “B” identify the complementary IP Addresses to which the communications are sent and the relative port.
E.G.: If the control panel does not dialogue via IP Addr “A”, it automatically reroutes communications to IP Addr
“B” and remains connected until a dialogue block occurs with this IP Addr. Only in this case will communications
return to IP Addr “A”.
IP Addr: Technical network parameter
Socket Port: Technical network parameter
User Password: this is the encrypting password, it is identical for both IP addresses and it must match the one
entered in the remote receiver.
Press (CLR) to vary
Enter number to be set
To access other entries press () or ()
Press (ENT) to conrm
Zones/Open Collector Parameters
Dialler
Email
Email
ENT 
SMTP Server
Socket Port
0
Sender
Username
Password
Encryption
NO
Authentication
NO
Email: this menu is used to set the parameters for sending events via email
SMTP Server: SMTP Server name. Parameter supplied by the service manager.
Socket Port: Technical network parameter
Sender: Enter the e-mail address or the name assigned to the control panel
Showed name: Enter the name of the sender of the e-mail address
Username: By setting Authentication to “YES”, this is the Username required to access the SMTP Server
Password: By setting Authentication to “YES”, this is the Password required to access the SMTP Server.
Encryption: By setting to “YES”, it sends the message encrypted with the SSL protocol
Authentication: By setting to “YES”, it uses access credentials to the SMTP Server (Username and Password)
Press (CLR) to vary
Enter number to be set
To access other entries press () or ()
Press (ENT) to conrm
Showed name
to following
page
from previus
page