Resetting to Factory Default Settings
To reset the AXIS 215 PTZ/AXIS 215 PTZ-E to the original default settings, go to the System Options >
Maintenance web page (described in
Maintenance, on page 35) or use the Reset button on the AXIS 215
PTZ/AXIS 215 PTZ-E as described below:
Using the Reset Button
Follow the instructions below to reset the AXIS 215 PTZ/AXIS 215 PTZ-E to factory default settings using the
Reset Button.
1. Switch off the AXIS 215 PTZ/AXIS 215 PTZ-E by disconnecting the power supply.
2. Press and hold the Reset button while you reconnect the power connector.
3. Keep the Reset button pressed for approximately 15 seconds.
4. Release the Reset button.
Note:
Resetting to the factory default settings using the Reset Button will cause all parameters (including the IP address) to be reset. Refer to
Maintenance, on page 35 for other methods that do not reset the IP address.