AXISP1365-ENetworkCamera
StatusLEDBehaviorforFocusAssistant
Color
Indication
Green
FocusAssistantisenabled
Thelensisoptimallyadjusted
AmberThecamerahasbeenmoved,oranobjecthasbeeninsertedinfrontofthelens.
ExitandrestarttheFocusAssistant.
Thelensislessoptimallyadjusted.
RedThecamerahasbeenmoved,oranobjecthasbeeninsertedinfrontofthelens.
ExitandrestarttheFocusAssistant.
Thelensispoorlyadjusted.
ConnectorsandButtons
Forspecicationsandoperatingconditions,seepage16.
NetworkConnector
RJ45EthernetconnectorwithPoweroverEthernet(PoE).
NO NO
NO
TICE TICE
TICE
Theproductshallbeconnectedusingashieldednetworkcable(STP).Allcablesconnecting
theproducttothenetworkshallbeintendedfortheirspecicuse.Makesurethatthe
networkdevicesareinstalledinaccordancewiththemanufacturer’sinstructions.For
informationaboutregulatoryrequirements,seeElectromagneticCompatibility(EMC)on
page2.
I/OConnector
Usewithexternaldevicesincombinationwith,forexample,tamperingalarms,motiondetection,
eventtriggering,timelapserecordingandalarmnotications.Inadditiontothe0VDCreference
pointandpower(DCoutput),theI/Oconnectorprovidestheinterfaceto:
DigitaloutputForconnectingexternaldevicessuchasrelaysandLEDs.Connected
devicescanbeactivatedbytheVAPIX®ApplicationProgrammingInterface,output
buttonsontheLiveViewpageorbyanActionRule.Theoutputwillshowasactive
(shownunderSystemOptions>Ports&Devices)ifthealarmdeviceisactivated.
DigitalinputAnalarminputforconnectingdevicesthatcantogglebetweenanopen
andclosedcircuit,forexample:PIRs,door/windowcontacts,glassbreakdetectors,
etc.Whenasignalisreceivedthestatechangesandtheinputbecomesactive(shown
underSystemOptions>Ports&Devices).