Care and Maintenance
4-15
PROBLEM POSSIBLE CAUSE SOLUTION
Throttle/shifting • Corroded cables. Clean and lubricate cables.
problems Defective throttle return Replace the throttle return
spring. spring.
Low transmission oil level. Replenish the transmission
fluid.
Sticking transmission Clean and lubricate detent
shift detent ball. ball.
Kink in cables. • Replace the cable(s).
See your dealer.
Steering problems Corroded cables. Clean and lubricate the
cable.
Rudder worn. See your dealer.
Excessive vibration. Damaged propeller. Replace the propeller.
Misaligned propeller shaft Check the alignment. See
coupling. your dealer for proper
realignment.
Bent propeller shaft. See your dealer.
Electrical problems Open circuit breaker or Reset the circuit breaker
blown fuse. or replace the fuse.
Loose wiring connections Clean and tighten wiring
or corrosion. connections.
Defective sending unit. Replace the sending unit.
Shorted wiring harness. Repair the wiring harness.
Defective switch or gauge. See your dealer.
No speedometer Paddle Wheel. Replace the paddle wheel.
Defective speedometer. Replace the speedometer.
Incorrect speedometer Paddle Wheel. Replace the paddle wheel.
Defective speedometer. Replace the speedometer.