EasyManua.ls Logo

Axis YP3040 - Change the DIP Switch Settings

Axis YP3040
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
YP3040Pan-TiltMotor
ChangetheDIPSwitchSettings
1.Loosenthefoursidepanelmountingscrewsandremovethesidepanel.
2.Settheeightswitchestoselectfunctions.Switches1,2,3,and4areusedtoselectthe
PTZcontrolprotocol.Switch7isalwaysOFF.Switch8isusedtoconnectaterminal
resistanceof120Ω,switchtoONwhenrequired.
Selectfunctions
1
23
45
6
7
8
ProtocolPelco-D
(default)
ONONOFFOFF
Pelco-P
OFFONOFFOFF
AD/AB
OFFOFFONOFF
Bitrate2400bps
OFFOFF
4800bps
ONOFF
9600bps
OFFON
19200bps
ONON
Terminal
resistance
OFF(default)
OFF
120Ω
ON
OFF
3.Setthe8switchestoselectaddress.
Selectfunctions
1
23
45
6
7
8
1(default)
ONOFFOFFOFFOFFOFFOFFOFF
2
OFFONOFFOFFOFFOFFOFFOFF
3
ONONOFFOFFOFFOFFOFFOFF
4
OFFOFFONOFFOFFOFFOFFOFF
5
ONOFFONOFFOFFOFFOFFOFF
..................................
254
OFFONONONONONONON
255
ONONONONONONONON
12

Table of Contents