53
3-20 Codabar
Read:
Format
Start
Data digits (variable)
Check digit (optional)
End
Check digit verification: The check digit is made as the sum module 16 of the numerical values of all
data digits.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of 3-16 Code 39.
Code ID setting: Refer to Code ID setting of 3-11 UPC-A.
Insertion group selection: Refer to Insertion group selection of 3-11 UPC-A.
Start/End type: Codabar has four pairs of Start/End pattern, you may select one pair to match your
application.
Start/End transmission: Refer to Start/End transmission of 3-16 Code 39.
Start/End character equality: By setting Enable, the start and end character of a Codabar barcode
must be the same.
Multiple-scan setting
Single-scan setting
Option barcode
Option
Alpha. entry
Read
Disable
00
Enable
01*
*
Check digit verification
Disable
00*
*
Enable
01
Check digit transmission
Disable
00*
*
Enable
01
Max. code length
00-99
00-99
99*
*
Min. code length
00-99
00-99
04*
*
Code ID setting
00-FF
16
(ASCII)
00-FF
16
<N>*
*
Insert group selection
00-44
00-44
00*
*
Start/End type
ABCD/ABCD
00*
*