EasyManuals Logo

B-TEC Starter 01 User Manual

B-TEC Starter 01
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
Spray-gun cleaner Starter Page 11
equipment and facility engineering
4.3 Safety regulations pertaining to the installation of B-TEC machines
The risk zoning around the cleaning machine and the possible creation of an explosion protection
document is, in accordance with legal requirements, the operator´s obligation, because this division
is inter alia depending on the solvents used and various conditions such as the ventilation. However,
at this point the operator should be supported with general advice to comply with the obligation.
Helpful advice can also be read at BGR 104, BGR 180 and DIN EN 12921-1 and -3.
For example, in many cases the classification of the zones looks like this:
Zone 0 => The interior of the machine
Zone 2 => In periphery of 1,0 1,5 m
Identify the different zones with appropriate warning and prohibition signs. Marks at the floor can be
helpful. In the area surrounding the unit, open flames and other ignition sources (e.g. welding or
grinding equipment places) are not allowed. Similarly, smoking is prohibited. Temporary work with
ignition must be approved in writing and appropriate additional safety precautions must be adhered
to (remove all combustible materials, classification of a fire station, ...).

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the B-TEC Starter 01 and is the answer not in the manual?

B-TEC Starter 01 Specifications

General IconGeneral
BrandB-TEC
ModelStarter 01
CategoryController
LanguageEnglish