StandardGuide line is parallel to the feed dog hole of needle plate. Match the
center position of guide line with the center needle position.
6. Press (#1). The guide line moves to the center.
7. Turn the pulley until the needle point comes to the needle plate
surface. Then check the position of guide line and needle.
In case not same,
7-1. Press (#2) to adjust the guide line position.
7-2. If you can not adjust by pressing (#2),
Loosen the 2 screw (#3) of laser module, then adjust te guide
line position.
8. Press ”CLOSE”.
2 of 2
#3
Laser module
#1
#2
Guide Line Position